Integration of Six Sigma Methodology to Reduce Complications in a Private Hemodialysis Center
View/ Open
Date
2015Author
Ekinci, Celil Gokay
Taner, Mehmet Tolga
Erbas, Engin
Metadata
Show full item recordAbstract
This paper aims to evaluate the complications occurred during and after the
hemodialysis sessions made in a private hemodialysis center in terms of their sigma levels and
severity. Complications with sigma levels under 4.00 indicate that the sessions need improvement and
corrective actions. Vital few and trivial many critical to quality (CTQ) factors are determined and
some improvement suggestions are made for the process based on the vital few CTQ factors.
Consequently, it is found that the hemodialysis process operates at a 3.5342 sigma level.